|
In this page you can find only some of the products that we can offer you. If you have any particular request, or want more information, please
This e-mail address is being protected from spambots. You need JavaScript enabled to view it
. We'll be pleased to give you all the answers you need.
Infusion sets with macrodrip for bag

CODE
|
DESCRIPTION |
PACKAGING |
|
Infusion set 1 way for bags with macrodrip chamber 20 drops/ml with solution filter and roller |
|
| IS654098-O |
Male luer lock with cap |
200 |
| IS654083-O |
Y connector with injection site and Male Luer Lock with cap |
200 |
| IS655166-O |
3 ways stopcock and Rotating Male Luer lock with cap |
200 |
| IS655180-O |
3 ways stopcock, Y connector with inj site latex-free and male Luer Lock with cap |
200 |
| CODE |
DESCRIPTION |
PACKAGING |
IS246004-O
|
Infusion set 1 way with macrodrip chamber 20 drops/ml without solution filter with roller and universal connector |
|
Infusion sets with macrodrip for bottles or rigid containers

| CODE |
DESCRIPTION |
PACKAGING |
|
Infusion set 2 ways with macrodrip chamber 20drops/ml with solution filter 15 μ, roller |
|
IS154098-O
|
Male luer lock with cap |
300 |
IS154023-O
|
Latex-free flashball and Male Luer Lock with cap |
300 |
| IS154083-O |
Y connector with injection site and Male Luer Lock with cap |
300 |
| IS154083-O |
Y connector with injection site and Rotating Male Luer Lock with cap |
300 |
| IS028923-O |
Latex-free flashball and male Luer Lock with cap, packed in PE envelope |
400 |
| CODE |
DESCRIPTION |
PACKAGING |
|
Deflussore a 2 vie con vaschetta macrogoccia 20 gg/ml senza filtro soluzione, roller |
|
IS024010-O
|
Latex-free flashball and Simmetric Luer with cap, packed in PE envelope |
400 |
IS038523-O
|
Latex-free flashball and Male Luer Lock with cap |
300 |
DEHP-free PVC infusion sets
| CODE |
DESCRIPTION |
PACKAGING |
|
Infusion set 2 ways with macrodrip chamber 20drops/ml with solution filter 15 μ, roller |
|
| IS164098-O |
Male luer lock with cap |
300 |
| IS164023-O |
Latex-free flashball and Male Luer Lock with cap |
300 |
| IS164083-O |
Y connector with injection site and Male Luer Lock with cap |
300 |
| IS164086-O |
Y connector with injection site and Rotating Male Luer Lock with cap |
300 |
Infusion sets with microdrip

| CODE |
DESCRIZIONE |
PACKAGING |
|
Deflussore a 2 vie con vaschetta microgoccia 60 gg/ml con filtro soluzione 15 μ, roller |
|
| IS216023-O |
Para latex-free e Luer Lock Maschio con cappuccio |
200 |
| IS216083-O |
Raccordo Y con punto iniezione latex-free e Luer Lock Maschio con cappuccio |
200 |
| IS216086-O |
Raccordo Y con punto iniezione latex-free e Luer Lock Girevole con cappuccio |
200 |
Amber-coloured infusion sets for use with photosensitive drugs

| CODICE |
DESCRIZIONE |
PACKAGING |
|
Infusion set 2 ways amber coloured for photosensitive solutions with macrodrip chamber 20 drops/ml with solution filter 15 μ, roller |
|
| IS215020-O |
Latex-free flashball and Male Luer Lock with cap |
250 |
| IS215090-O |
Y connector with latex-free injection site and Male Luer Lock with cap |
250 |
| IS215091-O |
Y connector with latex-free injection site and Rotating Male Luer Lock with cap |
250 |
| IS215021-O |
Latex-free flashball and Male Luer Lock with idrophobic air filter |
250 |
|
|
A flow regulator has two graduated scales: the first one (from 5 to 250 ml/hr), with blue numbers on a white background, must be used for solutions with a viscosity ≥ 10% (solution with a base of NaCl 9%, or Glucose 5% and 10%, or Mannitol 5% and 10%); the second one (from 5 to 200 ml/hr), with white numbers on a blue background, must be used for solutions with a viscosity of 10-40%.
As it can be seen on a regulator, the number 20 of the first scale has not the same value of the same number on the other scale. This is because the viscosity of the solution to be administrated to the patient is an important parameter to be consider during the calculation of the solution quantity. The regulators can’t be used for the administration of blood or blood components.
Solutions with high viscosity can cause a lower flow than the one indicated on the scale. Compensation for this problem can be achieved by increasing the height between the container of the solution and the patient. The use of a15 micron filter into the drip chamber is suggested, in order to prevent crystals from blocking the fluid path inside the regulator. Drop counting is always necessary to confirm proper flow rate. If necessary, the height of the I.V. solution containercan be adjusted to increase or decrease the flow rate.
EXAMPLE:
Drip chamber 20 drops/ml
200 ml/h = 66 drops per minute
100 ml/h = 33 drops per minute
50 ml/h = 16 drops per minute
The main used item is the extension line composed by:
- A female Luer Lock for standard connection to the male Luer Lock of infusion sets
- A Y connector with injection site for unexpected infusions
- A male Luer Lock for standard connection to the intravenous catheter
The other two main items are the infusion sets. They are different only for the drip chamber and so for the dropper:
- If the drip chamber has a dropper of 20 drops/ml, then the infusion set is called “Macrodrip”
- If the drip chamber has a dropper of 60 drops/ml, then the infusion set is called “Microdrip”
These three main items could be manufactured in these variants:
- Flow regulators with single scale
- Flow regulators with double scale for solutions with higher viscosity
- Flow regulators with amber coloured components for the administration of photosensitive drugs
- Flow regulators with PVC-FREE components for the administration of chemotherapy drugs
- Flow regulators with in-line absolute filters for the administration of Taxani
- Flow regulators with swabable needle-less valves for the administration in closed system
- Flow regulators with stopcocks or manifolds for connection of side lines
Extension lines

| CODE |
DESCRIPTION |
PACKAGING |
| FL1 001 O |
PVC tube - Male Luer Lock |
100 |
| FL1 008 O |
PUR tube - Male Luer Lock |
100 |
| FL1 101 O |
PVC tube - Rotating Male Luer Lock |
100 |
| FL1 108 O |
PUR tube - Rotating Male Luer Lock |
100 |
| FL1 201 O |
Double scale - PVC tube - Male Luer Lock |
100 |
Infusion sets with macrodrip
| CODE |
DESCRIPTION |
LUER-LOCK |
PACKAGING |
| FL1 002 O |
PVC |
Male |
100 |
| FL1 006 O |
Drip chamber PVC-FREE / tube PUR |
Male |
100 |
| FL1 102 O |
PVC |
Rotating |
100 |
| FL1 106 O |
Drip chamber PVC-FREE / tube PUR |
Rotating |
100 |
| FL1 201 O |
Doppia scala – PVC |
Male |
100 |
Infusion sets with microdrip

| CODE |
DESCRIPTION |
LUER-LOCK |
PACKAGING |
| FL1 003 O |
PVC |
Male |
100 |
| FL1 007 O |
Drip chamber PVC-FREE / tube PUR |
Male |
100 |
| FL1 103 O |
PVC |
Rotating |
100 |
| FL1 107 O |
Drip chamber PVC-FREE / tube PUR |
Rotating |
100 |
| FL1 203 O |
Double scale - PVC |
Male |
100 |
Amber coloured infusion sets

| CODE |
DESCRIPTION |
LUER-LOCK |
PACKAGING |
| FL1 005 O |
Amber PVC tube
|
Maschio |
100 |
| FL1 105 O |
Amber PVC tube
|
Girevole |
100 |
| FL1 004 O |
Macrodrip infusion set Amber PVC |
Maschio |
100 |
| FL1 004 O |
Macrodrip infusion set Amber PVC |
Girevole |
100 |
| FL1 109 O |
Macrodrip infusion set Amber PVC |
Girevole |
100 |
| FL1 109 O |
Macrodrip infusion set Amber PVC |
Maschio |
100 |
|
|
A burette is a cylindrical container with a capacity of 100 or 150 ml, with a printed graduated scale. It is used to prepare cocktails of drugs and physiological liquid (burette set for infusion) or to mix drugs and blood/plasma (burette set for transfusion). It can be used for enteral or parenteral feeding as well, especially in pediatric ward.
Our burette set is composed by:
- A spike fixed on the entrance tube, to link to bags or bottles;
- A cylindrical container with a floating valve inside it, that has the function of indicating the solution's level and of stopping the drug flow to the patient when it reaches the bottom (zero level);
-
Two covers:
- the upper one, together with the hole for the insertion of the tube, has an antibacterial air filter that allows the outlet of air. It also has an injection site for unexpected infusions;
-
the lower one has a central hole for the outflow of the drugs and it can be linked to :
- a micro or macro drip chamber with solution filter (burette set for infusion)
- a drip chamber with blood filter (burette set for transfusion)
- a macrodrip chamber without solution filter (burette set for parenteral infusion)
- a tube with inner Ø 4,3 or 4,8, with a snap off membrane (burette set for enteral feeding)
In burette sets for infusion or transfusion there are a roller, an injection site and a Luer or Luer Lock connector to link to the patient as in standard infusion sets.
100-150ml burettes
| CODE |
DESCRIPTION |
PACKAGING |
|
Graduated Burette Set for infusion with 2 ways spike microdrip chamber 60 drops/ml with solution filter 15 μ, roller and Y connector with injection site latex-free
|
|
| BG100600-O |
capacity 100 ml. Male Luer Lock with cap |
50 |
| BG100601-O |
capacity 100 ml. Rotating Male Luer Lock with cap |
50 |
| BG150600-O |
capacity 150 ml. Male Luer Lock with cap |
50 |
| BG150601-O |
capacity 150 ml. Rotating Male Luer Lock with cap |
50 |
| BG100650-O |
AMBER COLOURED capacity ml.100 male Luer Lock with cap |
50 |
| BG150650-O |
AMBER COLOURED capacity ml.150 male Luer Lock with cap |
50 |
Burette sets for enteral feeding
| CODE |
DESCRIPTION |
PACKAGING |
|
Graduated Burette Set for infusion with 2 ways spike drip chamber without solution filter, roller, Y connector with injection site latex-free and universal nutrition connector |
|
| BG100800-O |
capacity 100 ml.
|
50 |
| BG150800-O |
capacity 150 ml.
|
50 |
|
|
|
|
|
|